Welch Allyn CP 100 ECG Machine

  • Sale Price: £2,199.00
  • Availability: Usually dispatched within 6-10 business days

Features

  • A 12-lead resting ECG that provides accurate measurements
  • Optional MEANS ECG interpretation software for a second opinion
  • High-resolution thermal printer generates full-sized standard and customized reports
  • Lead quality graphic saves valuable time by highlighting poor connections
  • Full alphanumeric keyboard and LCD screen for easy patient data entry

Product Details

  • ASIN: B0043ETY0G
  • Item model number: CP100
  • Average Customer Review: Customer Reviews

Product Description

Specifications Dimensions: 15.6 in (39.7 cm) X 6.2 in (15.7 cm) X 16.2 in (41.1 cm) Weight: 11.6 lb (5.3 kg) Keyboard type: Elastomer keypad with complete alphanumeric keys Paper type: 8.25 x 11 inches (21 x 28 cm), Z-fold thermal paper, 200 sheets Thermal printer (internal): Computer-controlled dot array, 8 dots/mm Thermal paper speeds 10, 25, 50 mm/s Gain settings: Auto ECG's: 5, 10, 20 mm/mV, AUTO Rhythm ECG's: 5, 10, 20 mm/mV Report print formats: Auto ECG's: 3x4, 3x4+ 1R, 3x4 +3R, 6x2, 12x1, 6x2 50 mm/s, 6x2 Ext. Rhythm ECG's: 3 leads at a time Average cycles: 3x4 50 mm/s + 3R, 6x2 50 mm/s + 6R Frequency range: 0.3 to 150 Hz Digital sampling rate: > 1,000 samples/second/channel Pacemaker detection: ANSI/AAMI EC11 Power requirement: Universal AC power supply 100-240 V ~, 50/60 Hz ~, 2.2 A maximum Fuses AC: Time-delay type, 2 amp 250 V rating, Littlefuse 0215002 or equivalent. DC (battery fuse): Fast-acting type, 10 amp 32 V rating, Bussman ATC-10 or equivalent. Lead configurations: Standard, Cabrera Rechargeable battery: Lead acid gel, 6 volt, 5 AH Prints up to 100 continuous ECG's per charge 12-hour recharging Filters: 0.5 Hz high-performance baseline filter 35 Hz muscle-tremor filter AC-interference filter 50 Hz or 60 Hz Safety, EMC, and regulatory compliance: ANSI/AAMI EC11* UL60601-1 CAN/CSA C22.2 No. 601.1 IEC/EN 60601-1 CAN/CSA C22.2 No. 601.1.1 IEC/EN 60601-1-1 CAN/CSA C22.2 No. 601.1.2 IEC/EN 60601-1-2 CAN/CSA C22.2 No. 601.1.4 IEC/EN 60601-1-4 CAN/CSA C22.2 No. 601.2.25 IEC/EN 60601-2-25 Standard connectivity: SD memory card slot (for use with cards ? 64 MB) Connectivity with electronic medical records: Supported through the Welch Allyn CardioPerfect workstation software Electrodes: Rigorously tested for conductivity, adhesion, and hypoallergenic qualities, and exceed all AAMI standards Cables and wires: Meet or exceed IEC 60601 Environmental operating conditions: Temperature: +10° C to +40° C (+50° F to +104° F)

Customers Who Bought This Item Also Bought