Product Details
Product Description
For photovoltaic installations
With AC type 2 surge arrester, lightning protection switch and circuit breaker differential 30mA
Consistent with UTE C15-712-1
Fitted and pre-wired in Cabinet IP65
Warranty: 2 years
Presentation
According to standard UTE C15-712-1 which refers to guide UTE C 61-740-52, surge protection is mandatory side AC in the presence of lightning or lightning strike density greater than 2.5 (the density of lightning strikes is established by Department).
Assembled by AIGER AC surge protection cabinet can meet this standard and is intended for the protection of the photovoltaic installations downstream of the DC/AC converter.
All our lightning arrester boxes comply with IEC 60364-7-712 'Facilities in the building - part 7-712 - rules for facilities and special locations - photovoltaic power supplies'
The surge AC box consists of a modular Cabinet in which are installed and pre-wired:
1 interrupter-neutral 30mA type has high immunity (3KW), 25A (5KW) 16A or 32A (7KW)
1 AC type 2 surge arrester which provides effective protection on the phase and the neutral
1 circuit-breaker 16 A protection of the SPD
Choice of the size of the circuit breaker depending on the installation power 30mA differential:
16A (Ref.AIGCPARAFAC16A): for installations up to 3KW
25A (Ref.AIGCPARAFAC25A): for installations up to 5KW
32A (Ref.AIGCPARAFAC32A): for installations up to 7KW
Characteristics of the SPD
Surge AC 1 p + N type 2
Withdrawable cartridges
Common and differential mode protection
Maximum continuous operating voltage: 275VAC
Nominal discharge current: 20ka peak current
Maximum discharge current: 40kA
Level of protection under the rated current: 1, 2kV
Leakage current: < 1mA
Response time: < 25ns
Allowable short-circuit current: 25kA / 50 Hz
Connectio